5
Chief Property Parameters
SK Series
Item/Mode SK Series SK Series
Rated Cooling Capacity(W) 3200 3300
Rated Heating Capacity (W) 3530(Heat) 3630(Heat)
Rated Power Input (V/HZ) -220V/50HZ -220/50HZ
Rated Cooling Power Input(W) 860 920
Rated Cooling Input Current(A) 3.9 4.2
Max Cooling Power Input(W) 1480 1540
Max Cooling Input Current(A) 6.7 7.0
Rated Heating Power Input(W) 860/1360 920/1420
Rated Heating Input Current(A) 3.9/6.2 4.2/6.5
Max Heating Power
Input of Heat Pump (W)
860/1360 920/1420
Max Input Current of
Heat Pump (A)
3.9/6.2 4.2/6.5
Auxiliary Electric Heating
Rated Power Input(W)
1000 1000
Auxiliary Electric Heating
Rated Input Current (A)
4.54 4.54
Inhaling Maximum
Working Pressure(MP)
0.8 0.8
Exhausting Maximum
Working Pressure(MP)
2.8 2.8
Amount of Added Refrigerant (Kg)
970g 970g
Air Circulation of Outdoor Unit(M
3
/H)
570 550
Waterproof Grade 1PX4 1PX4
Outdoor unit 35 35
Net Weight (KG)
Indoor unit 12 12
Outdoor unit 760*300*685 760*300*685
Dimensions(MM)
length*height*width
Indoor unit 845*285*336 845*285*336
Outdoor unit <50 <50
Noise Level (DB)
Indoor unit <39 <39
Note:1. Parameters in the form are measured in the rated working state according to
GB/T7725-
2004. Changes may appear according to the real working state.
2 Parameters may change due to the product improvement.
Please refer to the products nameplate.
Comentarios a estos manuales